Skip to product information
1 of 1

BuildYourCNC

Coupling Spider (goes between two coupling hubs)

Coupling Spider (goes between two coupling hubs)

Regular price $3.00 USD
Regular price Sale price $3.00 USD
Sale Sold out
Title

This is the middle section of the coupling set. You will only need one of these to complete a set for one motor and one lead screw. Note: To create a complete coupling set, you will need two hubs (one for the motor shaft and one for the lead screw end) and you will need one spider. These items are only offered to allow for any configurations that is not offered for rigid couplings.

View full details

Questions & Answers

Have a Question?

Ask a Question
  • WE ARE PERFORMING DIGITAL X RAY USING A 9 OR 15 MEV LINATRON. THE CAMERA NOT IN DIRECT BEAM PATH. TO SHIELD USED 2.5-INCH THICK TUNGSTEN. NOW FIND HAVE VERY HIGH NEUTRON DOSE WITHIN SHIELDED CONTAINER. WOULD SEEN THIS SAME PROBLEM LEAD TUNGSTEN WORSE? WHAT CAN DO ELIMINATE ACTIVATION CONTAINER? IT BE ENOUGH ADD BORON PLASTIC POWDER COAT

    The linatron is an industrial linear accelerator manufactured by Varian Medical Systems1. In a linatron, the electron beam strikes a target, producing bremsstrahlung which is then collimated with internal collimators and sometimes with external collimators. The target and internal collimator are typically made of some high-Z material such as tungsten. The accelerator head is usually shielded with lead or tungsten. Neutron production will take place in any material struck by an electron or bremsstrahlung beam above a threshold energy (Eth). The minimum threshold for photoneutron production in tungsten and lead is 6.19 MeV and 6.11 MeV, respectively (NCRP 1984). Thus a linatron operating at 9 MV will produce neutrons. The photoneutron spectrum from the accelerator head resembles that of a fission spectrum. The spectrum changes after penetration through the head shielding. Since the linatron is usually operated in a concrete-shielded room, room-scattered neutrons will further soften the spectrum. Neutrons are classified as: Thermal: En = 0.025 eV at 20�C; typically En < 0.5 eV (cadmium resonance) Intermediate: 0.5 eV 10 keV where En is the neutron energy. The neutrons observed at the camera location will consist primarily of neutrons leaking directly from the accelerator head, room-scattered neutrons, neutrons produced in the object to be imaged by the primary bremsstrahlung beam, and neutrons scattered from the object to be imaged. Since the camera is not in the direct-beam path, photoneutrons can only be produced in the shielding by leakage photons or photons scattered from the object to be imaged. Since leakage photons are typically only 1 percent or 0.01 percent of the primary beam or even lower, neutron production in the camera shielding from leakage photons can be considered negligible, as can neutrons produced by photons scattered from the object. Therefore changing the shielding from tungsten to lead will not significantly reduce the neutrons at the camera location. The camera can be shielded from neutrons with several inches of a hydrogeneous material such as polyethylene. If thermal neutrons are also of concern, polyethylene doped with 5 percent boron (borated polyethylene) can be used. Boron has a much higher cross-section than polyethylene for thermal neutron capture. Boron interacts with thermal neutrons by undergoing an (n,a) reaction producing 7Li, which then undergoes an isomeric transition by emitting a 0.478 MeV photon or gamma ray. These photons are much lower in energy than the thermal neutron capture gammas (2.2 MeV) from hydrogen in the polyethylene. A sandwich construction of tungsten (or lead), polyethylene, and tungsten (or lead) will work best.

  • is this L050?

    Yes, this coupling buna spider is compatible with the L050